HEBEIOUTAI ENVIRONMENTAL PROTECTION EQUIPMENT CO.,LTD.

DMF-ZM Right Angle Nut Electromagnetic Pulse Valve

DMF-ZM Right Angle Nut Electromagnetic Pulse Valve
Similar Products
  • TH Type Bucket Elevator

    The bucket elevator has the advantages of large conveying volume, high lifting height, stable and reliable operation, and long life. Its main performance and parameters conform to JB3926---85 "Vertica...

  • ZC Type Mechanical Rotary Blow Flat Bag Filter

    ZC Type Mechanical Rotary Blow Flat Bag Filter Introduction:The dust collector adopts a circular body structure with uniform force, good anti-knocking performance, compact structure, high-pressure blo...

  • HL Bucket Elevator

    Bucket elevators are mainly used to convey powder, granules and small pieces of material vertically or obliquely. The cross-section of the bucket elevator is small in size and takes up less space, whi...

The valve is imported from abroad (also known as the diaphragm valve) is the compressed air "switch" of the pulse bag filter dust cleaning system is controlled by the output signal of the pulse injection controller, and the filter bag is cleaned by the row (chamber). Ash, so that the dust collector's resistance is maintained within the set range, in order to ensure that the dust collector processing capacity and vacuum efficiency. It is suitable for the installation and connection of the airbag and the spray pipe of the precipitator. The two ends of the air inlet and outlet are provided with fixing nuts for installation, which is more convenient for installation and use.

DMF-ZM Right Angle Nut Electromagnetic Pulse Valve Features:

The DMF-Z electromagnetic pulse valve is a right-angle valve. The angle between the inlet and outlet is 90°. It is suitable for the mounting connection between the helium cylinder and the dust blower tube. The gas flow is unobstructed, and it can provide the turbulent gas flow that meets the requirements.

DMF-ZM Right Angle Nut Electromagnetic Pulse Valve working principle:

The diaphragm divides the electromagnetic pulse valve into two air chambers, front and rear. When the compressed air is turned on, the compressed air enters the rear air chamber through the throttle hole. At this time, the pressure of the air chamber presses the diaphragm against the output of the valve. The pulse valve is in the "closed" state.

The electric signal of the pulse injection controller causes the electromagnetic pulse valve armature to move, the air chamber vent hole opens after the valve, the rear chamber quickly loses pressure, the diaphragm moves back, the compressed air is blown through the valve outlet, and the electromagnetic pulse valve is "opened" status.

Pulse injection control instrument electrical signal disappeared, electromagnetic pulse valve armature reset, after the air chamber vent hole closed, the rear chamber pressure increased so that the diaphragm close to the valve output, the electromagnetic pulse valve is in the "closed" state.
Leave us Message
  • TEL:+86 13932733791
  • FAX:0317-8288592
  • EMAIL: info@senotay.com
  • ADDRESS:Botou Industrial Zone, Cangzhou City, Hebei Province