HEBEIOUTAI ENVIRONMENTAL PROTECTION EQUIPMENT CO.,LTD.

DMF-Z Right Angle Electromagnetic Pulse Valve

DMF-Z Right Angle Electromagnetic Pulse Valve
Similar Products
  • Round Skeleton

    Dust removal frame, also known as dust bag cage, is an indispensable accessory for bag filter, used as a frame to support dust filter bag, it can be compatible with six, eight, ten, twelve, sixteen, e...

  • KWD/RD Wide-Space Electrostatic Precipitator

    KWD/RD space electrostatic precipitator uses high-voltage DC electric field to make the dust particle charge in the dust-containing gas to deposit on the surface of the sedimentation level under the a...

  • Woodworking Dust Remover

    Most of the dust collectors in woodwork factories use centralized treatment system, which can save investment and facilitate management. The woodworking machinery in the furniture factory will produce...

DMF-Z Right Angle Electromagnetic Pulse Valve Product introduction:

The valve is imported from abroad (also known as the diaphragm valve) is the compressed air "switch" of the pulse bag filter dust cleaning system is controlled by the output signal of the pulse injection controller, and the filter bag is cleaned by the row (chamber). Ash, so that the dust collector's resistance is maintained within the set range, in order to ensure that the dust collector processing capacity and vacuum efficiency.

DMF-Z Right Angle Electromagnetic Pulse Valve Features:

The DMF-Z electromagnetic pulse valve is a right-angle valve. The angle between the inlet and outlet is 90°. It is suitable for the mounting connection between the helium cylinder and the dust blower tube. The gas flow is unobstructed, and it can provide the turbulent gas flow that meets the requirements.

DMF-Z Right Angle Electromagnetic Pulse Valve working principle:

The diaphragm divides the electromagnetic pulse valve into two air chambers, front and rear. When the compressed air is turned on, the compressed air enters the rear air chamber through the throttle hole. At this time, the pressure of the air chamber presses the diaphragm against the output of the valve. The pulse valve is in the "closed" state.

The electric signal of the pulse injection controller causes the electromagnetic pulse valve armature to move, the air chamber vent hole opens after the valve, the rear chamber quickly loses pressure, the diaphragm moves back, the compressed air is blown through the valve outlet, and the electromagnetic pulse valve is "opened" status.

Pulse injection control instrument electrical signal disappeared, electromagnetic pulse valve armature reset, after the air chamber vent hole closed, the rear chamber pressure increased so that the diaphragm close to the valve output, the electromagnetic pulse valve is in the "closed" state.
Leave us Message
  • TEL:+86 13932733791
  • FAX:0317-8288592
  • EMAIL: info@senotay.com
  • ADDRESS:Botou Industrial Zone, Cangzhou City, Hebei Province